Lauter Tun Design and Operation

Table: Design and operational parameters for the Lauter Tun for 10 t grist

Darcy Variable

 

Lauter Tun

Mash Tun

Mash Filter

 

Tun diameter  (m)

8

5

20 (58 chambers)

 

Grain bed loading (kg/m²)

200

500

30

 

Cycle time (min)

144

288

110

 

Brews per day

10

5

13

 

Milling system

Wet / six-roll dry

Two / four-roll dry

Hammer

Q

Wort flow rate (hL/h)

889.2

378

1522.9

K

Bed permeability (m²) 

3.084 x 10-11

9.72 x 10-11

      3.525 x 10-13

K

Relative permeability

87

275

1

DP

Maximum limit (bar)

0.1

0.1

0.3

A

Filtration surface area (m²) 

50

20

330

Mash Water  (L/kg)

3.3

2.5

2.7

Sparge water L/kg

4.0

5.0

2.8

Malt modification

Less well

Well

Less well

Mash temperature (˚C)

76

65

76

µ

Wort viscosity (mPa.s)

1.25

1.85

1.65

L

Grain bed depth (m)

0.5

1.0

0.05

                       

Point of reflection: We can see from the above table that the lauter tun strong worts flow rate Q, is more than twice that of the mash tun. Why do you think this is? Use the table to identify their differences and formulate the reasons that the lauter tun strong worts can be collected faster. Give yourself 5-10 min to think about this and then click ‘Next’ to continue with this lesson.

You have completed 0% of the lesson