Suggested Response - Q4

** Compare steam sterilisation versus hot water sterilisation for activated carbon filters. What are the relative advantages and disadvantages?

Response:

Steam sterilisation advantages over hot water sterilisation:

  • It regenerates the activated carbon.

  • It strips out the volatile components.

Steam sterilisation disadvantages:

  • It is more expensive.

  • It can easily short circuit in the bed, resulting in areas that may not be sterilised.

  • The vessel takes a long time to cool down before it can be put on line again.