Suggested Response - Q5

**You have been asked to design a water specification for a pale lager. You have been provided with the following parameters: 

Microbiological

Copper

Iron

Manganese

Nitrate

Sodium

Alkalinity

Calcium

Chlorine

Chloride

Magnesium

Sulphate

Zinc

Provide suggested levels and reasons for each of the parameters listed.

Response:

Parameter

Level (mg/L)

Reason

Microbiological

0

Microbiological infection can cause flavour taints and colloidal instability.

Copper

< 1

Maintain very low levels to help reduce any H2S or SO2, and as a yeast nutrient. Nothing higher, as it can become toxic to yeast and be an oxidation catalyst.

Iron

0

Iron inhibits yeast, causing incomplete saccharification and the beer to lack body and flavour. Iron also discolours foam and causes a metallic flavour. It is an oxidation catalyst affecting both colloidal and flavour stability.

Manganese

< 0.05

Low levels are a co-factor to yeast enzymes

Nitrate

0

Nitrate can become nitrite, which is toxic to yeast.

Sodium

0-25

At these levels, the sodium may contribute to a full and low-level sweet palate.

Alkalinity

0-40

Lower levels of bicarbonate prevent the pH of the mash and wort being too high, You want the water to be soft.

Calcium

50-75

Helps ensure correct mash pH and aids yeast flocculation and beer stability.

Chlorine

0

Prevents chlorophenol flavours, can be toxic to yeast.

Chloride

50-100

May provide fullness and sweetness in order to balance bitterness.

Magnesium

0-15

Low levels, to act as a co-factor to yeast.

Sulphate

50-100

Levels might support bitterness and dryness. Ratio with chloride at 1:1 may give a balanced beer.

Zinc

< 0.5

Yeast nutrient at these levels.